12w IP42 constant voltage power supply for led strip light
Specifications
Model | HVAC-12012A0732 / HVAC-24012A0732 |
Input Voltage | 200-240V |
Output Voltage | 12V / 24V |
Output Current | 1.0A / 0.5A |
Output Power | 12W |
Power type | Constant Voltage |
Case Material | Plastic |
Certificate | CE(LVD+EMC) , TUV , ROHS , IP42 |
Strong point | High reliability and Low price |
Size | 73*35*23.5mm |
Weight | 75g |
Protected functions | Short circuit/Over voltage/Over temperature |
Warranty | 2 years warranty |
Market | Europe / Australia / Asia |
Model Number | HVAC-12012A0732 | HVAC-24012A0732 | |
Output | DC Voltage | 12V | 24V |
Rated current | 1.0A | 0.5A | |
Current range | 0~1.0A | 0~0.5A | |
Rated power | 12W | 12W | |
Ripple and Noise(max.) Note4 | 120mVp-p | 240mVp-p | |
Voltage tolerance Note3 | ±4% | ±4% | |
Line regulation | ±1% | ±1% | |
Load regulation | ±2% | ±2% | |
Output groups | 1 | 1 | |
Set up time Note6 | 2000ms,50ms(at full load)230Vac | ||
Holding time(Typ.) | 15ms( at full load)230Vac | ||
Input | Voltage range Note 2 | 170~264Vac or 240~374Vdc | |
Frequency range | 47~63Hz | ||
Power factor(Typ.) | PF≥0.5/230V( at full load) | ||
Efficiency(Typ.) | 76.5% | 78.5% | |
AC current | 0.19A/230Vac | ||
Inrush current(Typ.) | Cold start:50A/230Vac | ||
Leakage current | <0.5mA/240Vac | ||
Protection | Over load | 103~140% of the rated output power | |
Protection mode: Hiccup mode, recovers automatically after the load reduced. | |||
Short circuit | Protection type: Hiccup mode, recovers automatically after fault conditions removed | ||
Over voltage | 12.5~18.0V | 25.0~35.0V | |
Protection type: Hiccup mode, recovers automatically after fault conditions removed | |||
Over temperature | 100℃±10℃(RTH2) | ||
Protection type: Shut down O/P voltage, recovers automatically after temperature goes down. | |||
Environment | Working temperature | -20℃~+40℃ | |
Working humidity | 10%~90%RH,non-condensing | ||
Storage temp. and humidity | -25℃~+75℃,5%~95%RH | ||
Temp. coefficient | ±0.05%/℃(0~40℃) | ||
Vibration | 10-300Hz, 1G 10min./cycle, period for 60min. each along X, Y, Z axes | ||
Safe and EMC | Safety standards | Compliance to EN61347-1,EN61347-2-13, IP42waterproof rating. | |
Withstand voltage | I/P-O/P:3.75KVac | ||
Insolation resistance | I/P-O/P:100Mohms/500Vdc 25℃/70%RH | ||
EMC Emission | Compliance to EN55015,(CISPR22),EN61000-3-2 class A,EN61000-3-3 | ||
EMC Immunity | Compliance to EN61547,EN61000-4-2,3,4,5,6,8,11, Surge (L-N:1kV;L/N-FG:2kV) | ||
Others | MTBF | ≥200Khrs,MIL-HDBK-217F(25℃) | |
Dimension | 73X35X23.5mm(L*W*H) | ||
Packing | Net weight:0.075Kg/PCS;100PCS/7.5Kg/box;(315X275X295mm) | ||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Derating may be needed under low input voltages. Please check the static characteristics for more details. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Ripple & noise are measured at 20MHZ of bandwidth by using twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 5.The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-confirm EMC Directive on the complete installation. 6.The start time was tested under the situation of cold star, continuous switching on/off may raise the start time. |
Features:
Constant voltage style power supply
Input voltage 200~240V
Cooling by free air convection
Fully encapsulated with IP42 level
100% full load burn-in test
Small volume, low weight and high efficiency
Protections for short circuit, over load, over voltage and over temperature
Applications
*Office lighting, Artwork lighting, Display case
*Home lighting
*Commercial lighting, such as Down light, Underground lamp, Panel light, Spotlight, Wall washer, etc.
*Hotel, Restaurant lighting
*Other public lighting
Write your message here and send it to us